Microbiological Safety Cabinet – Arias Labs System

PURICUBE NEO bsc 2
PURICUBE NEO bsc 3
PURICUBE NEO bsc
PURICUBE NEO bsc 2
PURICUBE NEO bsc 3
PURICUBE NEO bsc

Microbiological Safety Cabinet

0 Review(s)
in stock
SKU: SAFECUBE-BSC

Quick Overview

Class II Type A2 bio safety cabinet

– Air circulation : 70% recirculation & 30% exhaust through HEPA filter
– Digital Controller with LCD display
– FL lamp On/Off, UV lamp On/Off, UV lamp timer, Total using time
– Utility : gas cock & valve 1EA / air cock & valve 1EA
– Wall mounted consent 2EA
– Differential pressure gauge included
– HEPA filter : 0.3㎛ particle removal 99.995%
– Glass door : mono weight balanced sliding tempered safety glass 5mm
– Base stand included
– Power : 230V 50/60Hz

Product Description

Class II Type A2
Class ll type A2 biological safety cabinet that protects the user and lab environment from the biohazard factor and prevents cross contamination of various samples used in experiments.

Suitable for laboratories requiring higher levels of safety grade 2

Intake air and working chamber air are drawn to the under plenum of

the worktop bench ensuring user safety in assured.

70% recirculated air is filtered with the HEPA filter, ensuring product safety is assured.

30% exhausting air is emitted through the HEPA filter, which complies with

the environmental safety requirements of the laboratory.

 

Equipment that enables safe UV sterilizer

UV sterilization will affect microorganisms at the surface of work table.

While UV light is on, front reinforcement glass door protects the user by blocking UV rays.

Automatically turns off UV light when opening the door or turning on the fluorescent lamp.

 

Checking the life and performance of filters through a differential pressure gauge

Measure the pressure of the bottom HEPA filter to check the performance and lifespan of
the filter in real time, allowing more safe and effective testing.

 

Front-side 10 degree tilting design for user’s convenience

Ergonomic 10 degrees tilting design allows users to make a convenient posture during experiment,
which enables user’s neck, shoulders and back comfortable despite long work with the cabinet.
Also user’s eyes can be protected from the reflection of light to the glass surface by this tilting design.

Strengthen sample and user safety

Protect specimen and user’s safety by inflow and downflow control.

Internal air pressure is maintained with negative pressure compared to the outside, preventing
the contaminated air from escaping through the gaps.

 

High performance motor to maintain the set airflow velocity

Regardless of filter loads, airflow velocity can be maintained at the set value through the
high performance motor

Easy and quick maintenance due to short filter replacement time

The filters can be replaced in any direction in front or upper of the cabinet, minimizing the time required
for maintenance to be maintained regardless of the installation conditions.

Strengthen validation support using higher performance filters

HEPA filter that enables to remove 99.995% of particles that
have a size greater than or equal to 0.3㎛

Optional ULPA filter that enables to remove 99.9995%
of particles that have a size greater than or equal to 0.12㎛

 

MODEL

SAFECUBE NEO 900

SAFECUBE
NEO 1200
SAFECUBE
NEO 1500

SAFECUBE
NEO 1800

ORDER CODE

PCN-9-MB

PCN-12-MB PCN-15-MB

PCN-18-MB

Size Inner(W x D x H)mm

 900x578x621

 1200x578x676   1500x578x676

 1800x578x653

Out(W x D x H)mm

 970x788x2080

 1270x788x2080   1570x788x2080

 1870x788x2080

Weight(Kg)

 190

 225   250

 280

Base Stand(H)mm

Stand 705(Included Caster 82)

Type

Class Ⅱ A2 (70% recirculation as downflow & 30% exhaust as outflow)

Controller Display

Back light LCD display

Function

FL lamp On/Off, UV lamp On/Off, UV lamp timer, Total using / Filter using time

Door

Weight balanced sliding tempered safety glass(5mm thick)

Worktop Material

Stainless steel plate 304, HL

Inside Material

Stainless steel plate 304, HL

Outside Material

Epoxy powder coated steel plate

Filter

H-14 HEPA filter : 99.995% at 0.3㎛ / ISO class 5

Average Airflow Velocity

Inflow

 0.45 m/s ± 0.025 m/s

Downflow

 0.30 m/s ± 0.06 m/s

Gas Valve

1EA

Air Valve

1EA

Consent

2EA with reinforced cover(mounted on inside wall)

UV Lamp

20W x 1EA 30W x 1EA

 40W x 1EA

FL Lamp  55W x 1EA  36W x 2EA

  55W x 2EA

Noise (dB)

< 65dBA
Power

AC 230V ± 10%, 50-60Hz, 1Phase

Safety

UV lamp automatic switch-off when door’s opened, Fuse installed each electric part,
Filter life span alarm with buzzer and display on screen